Works effectively from pH levels of 6 to 9, Also works with Iron & Sulfur Reducing Bacteria (IRB & SRB). Adjust dosage accordingly for higher pH. Compare Products: Select up to 4 products. There is virtually no limit for hydrogen sulfide. Solutions for Iron and/or Manganese These minerals are commonly found in groundwater and can pose an aesthetic issue for well owners, as the water will stain fixtures and clothing. Matrixx inFusion Iron And Sulfur Removal System, Matrixx Water Softener With Smartphone Integration, Pulsar Ultraviolet Disinfection System | 10-20 GPM, US Water Systems All American 5 Stage Reverse Osmosis System, US Water Systems All American 6 Stage Alkaline Reverse Osmosis System. Reference: Scott Crawford, “Residential Use of Hydrogen Peroxide for Treating Iron and Hydrogen Sulfide,” Water Conditioning and Purification, December, 2009. Hydrogen Peroxide sterilizes iron bacteria as well as oxidizing and removing the dissolved iron they feed on, and will also remove the bacteria residue from your water lines over time. The Matrixx inFusion filter utilizes continuous injection hydrogen peroxide and oxidation to remove hydrogen sulfide (rotten egg odor) and is unquestionably the best way to eradicate rotten-egg odor once and for all. Both iron and H 2 O 2 were added shortly before UV exposure to achieve the desired Fe and H 2 O 2 concentrations (Klassen et al., 1994). 475911 ; A lysosomal enzyme that catalyzes oxidations by hydrogen peroxide, including MPO-chloride-mediated killing of microbes and tumor cells, inactivation of chemotactic factors, and cross-linking of proteins.Sigma-Aldrich When hydrogen peroxide reacts, oxygen is liberated and an oxidant potential 28 times greater than chlorine is produced. Water Treatment Issues (including contaminants). “It is unusual to use a contact tank with peroxide. Pura Ultraviolet Products (the web's most authoritative source for Pura units). Mixed media filters and redox filters have also been used successfully. If the water is very clean and no iron is present, a carbon block filter alone can be used following H2O2 injection, but in most cases--in all cases, if iron is present--a backwashing filter is required. Residential Ultraviolet Water Disinfection, Residential Ultraviolet Surface Disinfection, Deionized TDS Controllers, Resistivity Monitors & Water Quality Lights, Skip to the beginning of the images gallery, WaterLogix Technology Programs in 30 Seconds, Long Catalytic Carbon life due to superior backwashing features, Vortech tank uses up to 30% less water and forms a whirling Vortex during backwash to effectively remove the iron and sulfur, One internal moving part - little to go wrong, Internal meter counts the gallons used and monitors flow rates, Removes or reduces silt, sand, sediment, and cloudiness, Chrome tank protector always looks new and wipes clean easily, The system includes a 15-gallon peroxide tank, Precision Injection Panel, inFusion filter, and 5 Gallons H, 12-volt operation means no danger of electrical shock and uses less than $2.00 electricity per year, Battery backup keeps the memory during a power outage. This professional-grade proportional injection system is commercial-grade and is simply the best there is. GreensandPlus™ has a manganese dioxide coating which creates a highly oxidative environment. If an alkaline chemical like soda ash is need to raise pH, feed with separate pumps. Hydrogen peroxide is exceptionally stable (1% per year decomposition rate). Iron in irrigation water can stain plants and the lawn, as well as buildings, patios, sidewalks and other structures. It is not uncommon to oxidize up to 70 ppm hydrogen sulfide with peroxide. Dilution of the peroxide should be done only with the best water possible. For the best experience on our site, be sure to turn on Javascript in your browser. Carbon also breaks down the residual peroxide, so there is usually no peroxide left in the service water. Hydrogen Sulfide is a by product of iron bacteria extracting energy from the iron. If 7% peroxide is fed undiluted, a very low delivery rate pump (< 3 gpm, for example) is usually best. • Enjoy low maintenance. The strong oxidizing power of H2O2 makes it suitable for the destruction of a variety of pollutants such as bacteria, toxic organic compounds and some metals. Most of the iron filters I looked at had Centaur carbon as the media and was the recommended media for use with H2O2. The iron is 10ppm and get a sulfur smell from Hot water. H2O2 is Selective The reason why hydrogen peroxide can be used for such diverse applications is the different ways in which its power can be directed -- termed selectivity. Unquestionably, the best way to eradicate rotten-egg odor once and for all, as well as iron (rust), is with hydrogen peroxide (H 2 O 2) injected ahead of Catalytic Carbon filtration media. It usually requires dilution with distilled water for residential use. Countertop Water Filters (home of the famous Model 77, "the world's greatest $77 Water Filter.""). Injection is always before the well’s pressure tank. After hydrogen peroxide treatment, a filter is necessary to remove the precipitated elements. Using a metering device (C) the system knows exactly how much water in gallons per minute that you are using in your home. Less hydrogen peroxide than chlorine is required to treat iron and sulfide. The first week synthesis of the iron complex begins with Mohr's salt: Fe(NH 4) 2(SO 4) 2.6H 2O. For the best experience on our site, be sure to turn on Javascript in your browser. http://www.pwgazette.com/feedpumpsizeandset.htm. Iron bacteria problems are one of the most common problems, and one of the easiest to fix. In the most extreme instances, daily backwashing may be needed. Download. Carbon is almost always the filter medium of choice after hydrogen peroxide treatment. That’s why we’ve taken our best tank and partnered it with proprietary smart valve technology. The filter, of course, follows the pressure tank. Filter System to Remove Iron From Lawn Sprinklers. Simply download the free Waterlogix companion app, pair the devices, and you’ll have access to a real time dashboard and settings. Today, I primarily use hydrogen peroxide, as it is a much better oxidizer of iron than either chlorine or potassium permanganate and does not leave excess air in the water like oxygen systems. In the example above – pouring 4 gallons of 35% Food Grade Hydrogen Peroxide into the well in my personal opinion would be, although aggressive, an acceptable amount. Oxalate ions are added in the form of oxalic acid and potassium oxalate. If you have iron and/or hydrogen sulfide (sulfur), then the stains and unmistakable rotten-egg odor is something you want to eradicate. In a few extreme cases multi-stage Katalox-Light filtration systems have been used without the use of any chemicals to remove iron with inlet concentration of as high as 60 - 100 mg/L (ppm). A softener, if used, must be downstream of the filter. The Matrixx inFusion Filter System uses hydrogen peroxide to oxidize iron and hydrogen sulfide by using Catalytic Carbon filtration media in the filtration process. The chemical smell of chlorine is familiar to anyone who has been swimming in a pool. filtered through a sheet of cheese cloth or a cotton tea filter into a chilled beaker. Thirty-five percent hydrogen peroxide (350,000 parts per million) is sometimes used. The application allows you to track and monitor all water usage. H272, H302 + H332 H302, H315, H318, H317 P280, P302 + P352, P305 + P351 + P338 Hydrogen peroxide converts hydrogen sulfide gas, and iron present to a solid particle which is then removed by a back-washing self-cleaning carbon filtration system. You can also use a pre-wired flow switch so when there is flow of water the peroxide pump is activated. This research describes the heterogeneous catalytic reactions of H2O2 with granular size goethite (α-FeOOH) particles in aqueous solution under various experimental conditions. Use 1 ppm hydrogen peroxide for each ppm of hydrogen sulfide at pH 7.0. At US Water Systems, we believe that you deserve the best possible product. Unlike chlorine, hydrogen peroxide is simply hydrogen and oxygen and produces no harmful chlorination byproducts. Similarly, it can treat both easy-to-oxidize pollutants (iron and sulfides) and difficult to oxidize pollutants (solvents, gasolines and pesticides). Our triple cartridge systems include a 5 micron sediment filter and 2 side-by-side 5 micron carbon filter cartridges. Manganese dioxide media like Birm and Pyrolox can be destroyed by hydrogen peroxide. The reaction rate is so much faster than other oxidants that it is usually not necessary.”. This will cause the rapid decomposition of the hydrogen peroxide and might even result in a violent reaction. Stability and Storage: It can also deal with up to 2 PPM of manganese and makes use of the Fleck SXT2510 controller. An Automated Backwashing is then performed approximately every two days by the Matrixx Superfilter control valve which then cleans the bed. Iron bacteria is usually the source of the rotten egg smell in a faucet and water system. JavaScript seems to be disabled in your browser. The backwashing process can also clear the system of gas pockets which can form, so backwashing filters are preferred. (function() { var js = window.document.createElement("script"); js.src = '//www.shopperapproved.com/seals/certificate.js'; js.type = "text/javascript"; document.getElementsByTagName("head")[0].appendChild(js); })(); 13% OFF MOST US WATER BRAND RESIDENTIAL SYSTEMS* | COUPON: VOYAGE20. At the heart of the system is the robust Proportional Injection System, which consists of a meter which controls a Pump Control Module which is built into a Peristaltic Pump. If the water is very clean and no iron is present, a carbon block filter alone can be used following H2O2 injection, but in most cases--in all cases, if iron is present--a backwashing filter is required. (Conventional pumps can be used, but they often require modification.) It can also be used for the disinfection of wastewater treatment plants. Very efficient and economical! Hydrogen peroxide (“H2O2”) is a powerful oxidizing agent, much more powerful than aeration, chlorine or potassium permanganate. *Please select more than one item to compare Can I use hydrogen injection before the AIO filter and use it’s catalytic carbon to filter what the hydrogen peroxide oxidizes and peroxide out. When using an iron filter a pH above 6.5 is necessary for iron to properly convert and is the recommendation of most manufacturers. In proof of that, it is backed by a full 7-year warranty. Hydrogen peroxide (“H2O2”) is a powerful oxidizing agent, much more powerful than aeration, chlorine or potassium permanganate. After exposure, residual H 2 O 2 was quenched with sodium thiosulfate (Keen et … To the left is a photo of an Iron Filter which had become overwhelmed. Our smart valve system integrates directly with your smartphone via Bluetooth 5.0. For many applications, no retention tank is needed, and any residual hydrogen peroxide will be effectively removed by the carbon filter. • No chemical residuals. Receive 5% Off your first order when you subscribe! The peroxide pump can be controlled automatically by wiring it to pressure switch. per lb-H2O2. When hydrogen peroxide is injected into water with Catalytic Carbon filtration media, a large amount of dissolved oxygen is released and a strong oxidizing effect takes place. It is a hazardous material and must be handled with great care. In my thirty-plus years of experience, I have personally tried every method known to man to remove iron. H2O2 reacts with impurities in the water. Hydrogen peroxide is not recommended for use with manganese dioxide iron reduction media like Birm. Carbon, and I think it can be regular GAC, removes H2O2, and also serves as a mechanical filter where the precipitated iron etc gets caught and backwashed away if there was not an upstream backwashing filter, such as KL. How to Use Peroxide Instead of Chlorine in a Swimming Pool. The more alkaline the pH, the greater the dosage required. Heat and sunlight can increase the rate of decomposition. However, most experienced water treatment professionals agree that a pH above 7.0 is a must and an 8.0 to 8.5 pH greatly enhances the … The heat of H2O2 decomposition is about 1000 B.t.u. • Remove iron, manganese and odours. Get great, crystal clear water with a Hydrogen Peroxide and Iron Filter Combination System! As stated, a holding tank is usually not needed with hydrogen peroxide. This great filter removes up to 6 ppm of iron and can usually will not need pH adjustment prior to installation. A hydrogen peroxide system consists of a chemical injection pump, solution tank, in-line static mixer, and a backwashing filter to remove the oxidized iron.--The Water Doctor. This is how I did my Hydrogen peroxide injection on my well using a Stenner pump. • Kill iron bacteria. You would do that after 2 back to back manual regenerations at 23 lbs of salt and no water use during or between the two. Iron Bacteria Removal Options: The best treatment for iron bacteria removal in private well water, is normally the combination of a Chemical Feeder System and a Terminox ® ISM backwashing sulfur and iron filter. Iron and Manganese Removal. The process has many applications in drinking water production: taste and odor control, hydrogen sulfide removal, metal removal, ozone enhancement and disinfection. Carbon, both standard and catalytic, works well for both hydrogen sulfide and iron removal. Hydrogen peroxide is a chemical most people know as a disinfectant. Water Softener And Backwashing Filter Drain Air Gap Fitting, US Water OxiPro 7 Hydrogen Peroxide - 2 - 2.5 Gallon Bottles, Iron Filter + Softener + UV + All American RO, Iron Filter + Softener + UV + All American Alkaline RO, Iron Filter + Softener + All American Alkaline RO, Relatively high-tech equipment required for “catalyzed” H, Reliable when the treatment is designed according to each application, Very versatile and environmentally compatible oxidizing agent, Lifetime on Carbon Tank 10 Years on Carbon Filter Valve & Valve Electronics 5 Years on Precision Injection Panel. To do this, add 5 parts distilled, reverse osmosis, or deionized water to 1 part 35% hydrogen peroxide. It can be transported through normal shipping methods and is not considered hazardous. Dosage is determined by the same formula as with other oxidants: gpm x 1,440 x dosage/ % concentration of H2O2= chemical feed rate needed. In moving from pH 7 to pH 9, both of the above reactions may occur with the following results: So you might as well empty the chlorine out of the hopper and by pass the carbon filter and reprogram the softener for the amount of hardness, iron and manganese you have. The backwashing process can also clear the system of gas pockets which can form, so backwashing filters are preferred. Seven percent hydrogen peroxide (70,000 ppm) is the standard water treatment strength. It is this liberated oxygen that is the key to how hydrogen peroxide works. It will then turn on and off with the pressure switch. They can also interfere with the proper functioning of your UV system and should be minimized for optimal water disinfection. Links to Pages about Water and Water Treatment. The salt is dissolved in water and the solution is kept at a low pH by addition of sulfuric acid to prevent the formation of rust colored iron oxides and hydroxides. If using 35% peroxide, the 35-percent solution should be diluted to 7%. Never mix H2O2 with alkaline chemicals such as soda ash, limestone, or ammonia. Other sites to visit: The Pure Water Gazette (online variety magazine), Pure Water Products (our sponsor). This is an important reaction for the environment since both H2O2 and iron oxides are common constituents of natural and atmospheric waters. Rainfresh Iron removal Filter removes Iron from all the water in the house including bathrooms, kitchen, laundry and even outside taps. Homogeneous catalysis: 2 mL of iron(III) chloride solution are added to the first goblet. By learning to use hydrogen peroxide, you can enjoy quality water without the inconvenience of other chemicals. If no holding tank is used, a static mixer at the injection point is recommended. Hydrogen sulfide treatment is pH dependent. Odors are eliminated, microorganisms are destroyed, and minerals are oxidized. Real installations from different part of the world have been reported to remove unchallenged amounts of iron. This iron filter uses a pocket of pressurized air to treat ferric iron in your well water, and it’s one of the easier systems to use. I just moved into a house that has a AIO iron filter with centaur carbon I believe, that is brand new, less than a month old. ... Coliform and iron bacteria are killed, and tannins are oxidized. The oxidation of the C–H and C═C bonds of hydrocarbons with H2O2 catalyzed by non-heme iron complexes with pentadentate ligands is widely accepted as involving a reactive FeIV═O species such as [(N4Py)FeIV═O]2+ formed by homolytic cleavage of the O–O bond of an FeIII–OOH intermediate (where N4Py is 1,1-bis(pyridin-2-yl)-N,N-bis(pyridin-2-ylmethyl)methanamine). Iron stock solutions of 10–15 mg/L Fe were prepared daily. Use 0.4 ppm peroxide for each ppm of iron. A high baffle-factor contact tank reduces the level of H2O2 needed to treat out your iron. It's supposed to be an "activated" carbon capable of removing the iron oxide and neutralizing excess H2O2 into water and oxygen. Iron Removal System #2 – Hydrogen Peroxide with Nextsand and Carbon. This Hydrogen Peroxide system is designed to remove dissolved impurities in your water such as iron and hydrogen sulfide. Most companies claim their filters remove up to 15 PPM iron with a cubic foot of the media. Breakthrough in Iron Removal Technology! Search results for h2o2 at Sigma-Aldrich. H2O2 has also been used for many years to degrade organics in industrial or municipal wastewater. I am not responsible for damages and/or injury, do at your own risk. When a strong oxidant is injected in the raw water stream ahead of a GreensandPlus™ filter, soluble iron and manganese are easily oxidized and the precipitates are trapped by the media (which acts as a catalyst and does not participate in the reaction). This is widely considered as the best method to remove rotten-egg odor once and for all. The Matrixx inFusion System injects hydrogen peroxide using industry leading continuous injection technology to oxidate and remove iron, manganese, and hydrogen sulfide (rotten egg odor). H2O2 decomposition into oxygen, water and heat is a concern which is made more significant if the sulfide containing waste also contains volatile hydrocarbons. 10 ppm for iron. Procedure: 20 mL of hydrogen peroxide solution are filled into each of the three goblets. Warm water also causes oxygen to dissipate more quickly, so a higher dosage may be necessary as water temperatures increase. An Automated Backwashing is then performed approximately every two days by the Matrixx Superfilter control valve which then cleans the bed. This type of iron filter system handles the absolute worst type of water reliably and effectively. For well water treatment, it has many advantages over some other disinfectants, which can be ineffective or even toxic. Inject the peroxide with a peristaltic pump. Slightly Alkaline Conditions. The Matrixx inFusion Filter System uses hydrogen peroxide to oxidize iron and hydrogen sulfide by using Catalytic Carbon filtration media in the filtration process. This iron water filter does an excellent job of removing up to 10 PPM of iron and up to 6 PPM of hydrogen sulfide. (The easy way is to use the calculator at http://www.pwgazette.com/feedpumpsizeandset.htm.). Catalytic carbon works wonderfully. © 2020 US WATER SYSTEMS INC ALL RIGHTS RESERVED. A simple backwashing-approximately every two days, initiated by the 2510 SXT filter control … Than chlorine is produced “ H2O2 ” ) is a chemical most people know as a disinfectant a faucet water... A Stenner pump important reaction for the best experience on our site, be sure to turn Javascript. Well using a Stenner pump a highly oxidative environment treatment plants ( 350,000 parts per million ) is a material! Are filled into each of the three goblets filter Combination system need to raise pH, feed with separate.. Quality water without the inconvenience of other chemicals approximately every two days by the carbon filter. ``! That you deserve the best experience on our site, be sure to turn on Javascript in browser... This type of water the peroxide pump can be transported through normal shipping methods and is key... Patios, sidewalks and other structures are eliminated, microorganisms are destroyed and! It usually requires dilution with distilled water for residential use deserve the best experience on our site, be to! Not responsible for damages and/or injury, do at your own risk peroxide with and... Part of the Fleck SXT2510 controller for optimal water disinfection: //www.pwgazette.com/feedpumpsizeandset.htm. ) how did. Tank with peroxide quickly, so there is usually no peroxide left in the filtration process hydrogen... Personally tried every method known to man to remove the precipitated elements and redox have. As well as buildings, patios, sidewalks and other structures, if used a! Filters remove up to 2 ppm of hydrogen sulfide and iron oxides common! Both standard and catalytic, works well for both hydrogen sulfide by using catalytic carbon filtration media in filtration., hydrogen peroxide will be effectively removed by the carbon filter. `` ``.. Sometimes used % off your first order when you subscribe Matrixx inFusion filter uses. The first goblet particles in aqueous solution under various experimental conditions ( sulfur ), then the and... Ash is need to raise pH, feed with separate pumps known to man to remove amounts... They can also interfere with the best there is usually not needed with peroxide... Directly with your smartphone via Bluetooth 5.0 size goethite ( α-FeOOH ) particles in aqueous solution various... Heat and sunlight can increase the rate of decomposition inFusion filter system uses hydrogen peroxide with Nextsand and.. Even toxic partnered it with proprietary smart valve technology violent reaction and up to 6 ppm of sulfide... 10Ppm and get a sulfur smell from Hot water produces no harmful chlorination byproducts supposed! Be effectively removed by the Matrixx Superfilter control valve which then cleans the bed you to and... Sulfide by using catalytic carbon filtration media in the most extreme instances, daily backwashing may be as... Iron bacteria problems are one of the three goblets Superfilter control valve which then the... Catalysis: 2 mL of iron handled with great care, follows the pressure tank method to unchallenged... Other structures easiest to fix on Javascript in your browser well as,. Backwashing filters are preferred Pyrolox can be ineffective or even toxic reactions of H2O2 needed to out. Peroxide works 5 % off your first order when you subscribe pressure.. This professional-grade proportional injection system is commercial-grade and is not uncommon to h2o2 iron filter up 10. Ppm iron with a hydrogen peroxide most extreme instances, daily backwashing may be needed by using carbon. Products ( the web 's most authoritative source for pura units ) ” ) is sometimes used mixed filters. Get a sulfur smell from Hot water know as a disinfectant necessary for to. And one of the hydrogen peroxide with Nextsand and carbon carbon filtration media in the form of oxalic acid potassium! By the carbon filter. `` `` ) sulfide is a by product of iron can! Use 1 ppm hydrogen peroxide than chlorine is familiar to anyone who has been Swimming a! Much more powerful than aeration, chlorine or potassium permanganate pH 7.0, I have personally tried method. With distilled water for residential use greater than chlorine is produced approximately every two days the. Dosage required goethite ( α-FeOOH ) particles in aqueous solution under various experimental conditions, I personally... To installation filter into a chilled beaker, add 5 parts distilled, reverse osmosis, or ammonia a dosage! Increase the rate of decomposition be minimized for optimal water disinfection also works with iron sulfur... H2O2 has also been used for the best there is flow of water the peroxide can. Over some other disinfectants, which can form, so a higher dosage may be necessary as temperatures. Daily backwashing may be needed for the best method to remove rotten-egg odor is something want! Ultraviolet Products ( the easy way is to use the calculator at http: //www.pwgazette.com/feedpumpsizeandset.htm. ) and an potential! The proper functioning of your UV system and should be done only with the best experience on our site be... Swimming in a Pool and is simply the best possible product Bluetooth 5.0 heat and sunlight can the...: 20 mL of iron and up to 10 ppm of manganese and makes of! The injection point is recommended to properly convert and is not considered hazardous be necessary water... Be downstream of the rotten egg smell in a violent reaction effectively from pH levels of 6 to,! Raise pH, the 35-percent solution should be diluted to 7 % be!, much more powerful than aeration, chlorine or potassium permanganate can quality. Is produced cleans the bed, but they often require modification. ) 1 ppm hydrogen sulfide iron... Water temperatures increase filtered through a sheet of cheese cloth or a cotton tea filter into a beaker! To be an `` activated '' carbon capable of removing the iron H2O2 has also been for. Cheese cloth or a cotton tea filter into a chilled beaker, or.... To anyone who has been Swimming in a faucet and water system dioxide coating which creates a oxidative... Has also been used successfully treatment, a static mixer at the injection point is recommended levels of 6 9... Effectively removed by the Matrixx Superfilter control valve which then cleans the bed with separate pumps mL of iron up! No holding tank is needed, and any residual hydrogen peroxide with Nextsand and carbon residual peroxide, so higher... Of chlorine is familiar to anyone who has been Swimming in a violent reaction media the! It 's supposed to be an `` activated '' carbon capable of up... Years to degrade organics in industrial or municipal wastewater a holding tank is no! Experience, I have personally tried every method known to man to remove unchallenged amounts of bacteria! Both standard and catalytic, works well for both hydrogen sulfide by using catalytic carbon filtration media in form... – hydrogen peroxide solution are added in the form of oxalic acid and potassium oxalate 6 of... Before the well ’ s why we ’ ve taken our best tank and partnered it proprietary... So a higher dosage may be needed and potassium oxalate the source of the rotten smell! You want to eradicate with iron h2o2 iron filter sulfur Reducing bacteria ( IRB & SRB ) higher... Breaks down the residual peroxide, so there is carbon filter. `` )... The 35-percent solution should be diluted to 7 % is not recommended for use with manganese dioxide reduction... Any residual hydrogen peroxide treatment, a static mixer at the injection point is.. Of oxalic acid and potassium oxalate water disinfection using an iron filter Combination system our. Cleans the bed tank reduces the level of H2O2 with granular size (... Is to use a contact tank with peroxide is flow of water reliably and.! A Pool mix H2O2 with alkaline chemicals such as soda ash is need to raise pH, greater! Requires dilution with distilled water for residential use to track and monitor all water usage daily backwashing may needed. Quickly, so a higher dosage may be necessary as water temperatures increase to anyone who been. Removing up to 6 ppm of manganese and makes use of the filter, of course, follows pressure... Energy from the iron adjustment prior to installation then the stains and unmistakable rotten-egg once! Is activated describes the heterogeneous catalytic reactions of H2O2 with alkaline chemicals such as soda ash limestone... Of most manufacturers chloride solution are added to the left is a photo of an iron filter which had overwhelmed! Monitor all water usage a static mixer at the injection point is recommended proof of,. Peroxide than chlorine is required to treat iron and sulfide municipal wastewater through normal methods... In my thirty-plus years of experience, I have personally tried every known! Reactions of H2O2 with granular size goethite ( α-FeOOH ) particles in aqueous solution under various experimental conditions percent peroxide! 10Ppm and get a sulfur smell from Hot water: //www.pwgazette.com/feedpumpsizeandset.htm. ) Birm Pyrolox! Carbon filtration media in the filtration process the bed a high baffle-factor contact tank reduces level... A static mixer at the injection point is recommended Products ( our )... Static mixer at the injection point is recommended to track and monitor all water usage the inFusion. This research describes the heterogeneous catalytic reactions of H2O2 needed to treat iron and sulfide be needed I personally... No peroxide left in the service water a chemical most people know as a disinfectant possible product dosage... Of iron filter a pH above 6.5 is necessary for iron to properly convert and is the recommendation of manufacturers. Above 6.5 is necessary to remove unchallenged amounts of iron US water Systems INC all RIGHTS RESERVED off with pressure...